Microcomputer control Horizontal Pressure Steam Sterilizer BJ

  • Safety: Door won’t open till 0.027MPa, won’t start if door loose. Safety valve releases steam to water tank at 0.24MPa. Water – leak triggers power cut + alarm. Stainless steel chamber.

  • Specs: 0.22Mpa, 134℃ (40 – 134℃ adjust), 0 – 99min sterilize/dry, ≤±2℃ heat. Power 9 – 12KW, meet clinic/research sterilization needs with safety and efficiency.

Description

Technical Specifications

  • Microcomputer control Horizontal Pressure Steam Sterilizer Automatically controlled the sterilizing process, easy to operate: The microcomputer control system allows for precise and automated control of the sterilization process, making it user-friendly and ensuring consistent results.

  • The safety valve will be open automatically when the inner pressure is over 0.24MPa, and the steam would be exhausted into the water tank: This safety feature ensures that excess pressure is released safely to prevent any potential hazards. With drying function, suitable for medical dressing drying: The inclusion of a drying function is beneficial for ensuring that the sterilized items, especially medical dressings, are thoroughly dried after the sterilization process.

  • The door cannot be opened until the pressure in the chamber is reduced to 0.027MPa: This is a safety measure to prevent premature opening of the door, ensuring that the internal pressure has reached a safe level before allowing access. Automatically cut off the power if a water lack happens, and alarm at the meanwhile: This safety measure protects the sterilizer by cutting off power in the event of water shortage, with an alarm to alert users. inclusion of a printer allows for documentation and record-keeping of sterilization cycles, providing a traceable history of the sterilization process.

  • Automatically controlled the sterilizing process, easy to operate.
  • With drying function, suitable for medical dressing drying.
  • With over-temperature, over-pressure auto-protect.
  • The door can not be opened until the pressure in the chamber is reduced to 0.027MPa. And the unit can not be started if the door doesn't close well.
  • The safety valve will be open automatically when the inner pressure is over 0.24MPa and the steam would be exhausted in the water tank.
  • Automatically cut off the power if the water leak happens, and alarm in the meanwhile.
  • The chamber of the sterilizer is made of stainless steel.

MODEL/TECHNICAL DATA

WS 150YDB

WS-200YDB

WS-280YDB

Sterilizing chamber volume

150L

200L

280L

Φ440×1000mm

Φ515×1000mm

Φ600×1000mm

Working pressure

0.22Mpa

0.22Mpa

0.22Mpa

Working temperature

134℃

134℃

134℃

Temperature adjust range

40 - 134℃

40 - 134℃

40 - 134℃

Time for sterilization

0-99min

0-99min

0-99min

Time for drying

0-99min

0-99min

0-99min

Heat average

≤±2℃

≤±2℃

≤±2℃

Power

9kw/380V 50Hz

9kw/380V 50Hz

12kw/380V 50Hz

Dimension (mm)

1400×650×1820

1400×750×1700

1520×910×1900

Transport dimension(mm)

1560×860×1820

1560×910×1880

1680×1060×2050

G.W/N.W

430/340kg

436/350Kg

570/462Kg