Benchtop Centrifuge JTGF 80-2/80-2B/80-2C

  • This benchtop centrifuge, based on centrifugal separation technology, can separate heterogeneous mixtures composed of different particles, suitable for biochemical research such as cell collection and DNA extraction.

  • It has various centrifugal capacities (24×10ml, etc.), a rotating speed of 400-4000 rpm, supports 1-60 minutes timing or continuous operation, and has a 40W motor power.

  • The centrifuge uses a 220V 50Hz power supply with a relative centrifugal force of 2350×g, capable of plasma separation, virus extraction and other operations. When in use, it is necessary to ensure that the centrifuge tubes are placed symmetrically with equal amounts of substances. The operation steps include adjusting to the minimum rotating speed, setting the timing, and adjusting the speed slowly, etc.

Description

I. Overview

Centrifugal separation technology is a new technology developed based on the state of particles in practical centrifugal conditions. Particles with different densities, sizes, or shapes settle at different rates under centrifugal forces of varying speeds, allowing roughly spherical heterogeneous mixtures to be separated by centrifugation. This centrifuge is designed for further biochemical research and large-scale substance separation, such as cell collection, plasma separation, extraction of DNA and proteins from purified preparations, as well as isolation of viruses, large-scale Escherichia coli, cellular components, and nucleoprotein particles.

II. Main Technical Parameters

  1. Power Supply: AC 220V 50Hz

  2. Motor Power: 40W

  3. Rotating Speed: 400–4000 rpm

  4. Centrifugal Capacity: 24×10ml, 18×15ml, 12×20ml, 8×20ml

  5. Timing Range: 1–60 minutes or continuous operation

  6. Relative Centrifugal Force (RCF): 2350×g

III. Operating Instructions

  • The instrument should be placed on a stable workbench in a clean, tidy environment with moderate temperature, humidity, and good ventilation.

  • Before use, set the speed control knob to the minimum position.

  • Insert centrifuge tubes containing substances to be separated into the instrument’s dedicated holders. To ensure stable operation and avoid excessive vibration, the volume of substances in each tube must be approximately equal, and tubes should be inserted symmetrically. Close the cover.

  • Select the timing mode by turning the timer knob to “Timing” or “Continuous” position.

  • Connect the power supply, switch the power to “ON”—the indicator light will illuminate. Slowly adjust the speed control knob to the desired rotating speed.

  • Before shutting down, set the speed control knob to the minimum position, turn off the power switch, and disconnect the power supply.