Wall Mounted Type Plasma Air Sterilizer BJ
-
Plasma air sterilizers (BJ – 80B/BJ – 100B) use plasma to disinfect air, kill bacteria. Apply to medical (ORs, wards) and industrial (pharmaceutical, etc.) spaces, usable with people.
-
Filtration removes dust/bacteria. Dynamic (man – machine coexist) + static disinfection. Microcomputer/remote control, fault monitor, wind speed adjust, auto time count.
-
80/100m³ applicable volume, 90min time, 640/800m³/h air volume. 60VA power, 45db noise. High disinfection efficiency. Wall – mounted, 104×35×18cm.
Description
plasma air sterilizer mainly uses plasma as a sterilization factor, which can be used to sterilize indoor air, kill bacteria in the air, and can be used in human places. It is suitable for air disinfection in II, II, and IV environments of general operating rooms, delivery rooms, baby rooms, premature delivery rooms, supply rooms, burn wards and so on, as well as indoor air disinfection in pharmaceutical, food, school, public places, and other industries.
● Filtration and dust removal: the physical filtration method in air laminar cleaning technology is used to remove dust and bacteria from the air.
● Safe and reliable: this machine is dynamic air disinfection equipment, man-machine coexistence, harmless to people, no corrosion to equipment, but also can be used for static air disinfection in unmanned places.
● Convenient to use: All the machines have the functions of microcomputer program control, far infrared remote control, automatic monitoring of plasma fault, wind speed regulation, automatic accumulation of working time, and so on.
MODEL/Technical Data | BJ – 80B | BJ – 100B |
---|---|---|
Index applicable volume(m³)≥ | 80 | 100 |
Suggested time(min) with high wind speed | 90 | 90 |
Circulating air volume(m³/h)≥ | 640 | 800 |
Input power(VA)≤ | 60 | 60 |
Fuse(A) | 2 | 2 |
Noise db(A)≤ | 45 | 45 |
Plasma density | 4.08×10¹⁶/m³ – 1.37×10¹⁷/m³ | 4.08×10¹⁶/m³ – 1.37×10¹⁷/m³ |
Ozone content in working environment(mg/m³) | 0.02 | 0.02 |
Disinfection efficiency | Within 120 minutes, the extinction rate of the simulated experiment of Staphylococcus billycans is≥99.9%, and the extinction rate of the natural bacteria in the air in the field experiment is≥90%. | Within 120 minutes, the extinction rate of the simulated experiment of Staphylococcus billycans is≥99.9%, and the extinction rate of the natural bacteria in the air in the field experiment is≥90%. |
Installation size(cm) | 104×35×18 | 104×35×18 |
Installation mode | Wall hanging type | Wall hanging type |