Mobile Plasma Air Sterilizer FY PL-100Y
-
Plasma air sterilizers, with plasma as the sterilization factor, kill airborne bacteria, suitable for medical, pharmaceutical, food, schools and public places.
-
They feature filtration, safe human-machine coexistence, easy operation via microcomputer control, and efficient disinfection with low noise.
Description
Product description:
plasma air sterilizer mainly uses plasma as sterilization factor, which can be used to sterilize indoor air, kill bacteria in air, and can be used in human places. It is suitable for air disinfection in II, III, IV environment of general operating room, delivery room, baby room, premature delivery room, supply room, burn ward and so on, as well as indoor air disinfection in pharmaceutical, food, school, public places and other industries.
Product characteristics:
-
Filtration and dust removal: the physical filtration method in air laminar cleaning technology is used to remove dust and bacteria from the air.
-
Safe and reliable: this machine is dynamic air disinfection equipment, man-machine coexistence, harmless to people, no corrosion to equipment, but also can be used for static air disinfection in unmanned places.
-
Convenient to use: All the machines have the functions of microcomputer program control, far infrared remote control, automatic monitoring of plasma fault, wind speed regulation, automatic accumulation of working time and so on.
Main technical parameters:
Model No. |
PL-100Y |
PL-120Y |
Index applicable volume(m3)≤ |
100 |
120 |
Suggested time (min)with high wind speed |
90 |
90 |
Circulating air volume(m3h)≥ |
800 |
960 |
Input power (VA)≤ |
150 |
155 |
Fuse (A) |
2 |
2 |
Noise db (A)≤ |
45 |
|
Ozone content (mg/m’) |
4.08*1016/m3-1.37*1017/m3 |
|
Ozone content in working environment(mg/m3) |
0.02 |
0.02 |
Disinfection efficiency |
Within 120 minutes, the extinction rate of the simulated experiment of Staphylococcus albicans is ≥99.9%, and the extinction rate of the natural bacteria in the air in the field experiment is ≥90%. |
|
Installation size (cm) |
36*35*97 |
42*40*101 |
Installation mode |
Mobile type |
Mobile type |
Working environment conditions: temperature 5°C-40°C, humidity:≤85%.
Power supply-220V±22V 50Hz±1Hz, atmosphere Pressure 86kpa-106kpa.
Transportation conditions: the conventional mode of transport is adopted.
The ambient temperature is-20 °- + 50 °C and the relative humidity is less than 90%.