Patient Monitor SNP900N
12.1” TFT color LCD, 800*600dpi
Standard 5 para: ECG, SpO2, NIBP, TEMP, RESP
Fanless design, quiet, energy‑saving and clean.
With standard interface, OxyCRG, trend chard, big character interface and view bed,
Operation mode: keys and buttons.
Display up to 8‑channel waveform on one screen.
NIBP measurement mode: Manual/AUTO/Continuous, storage for 1000‑group NIBP data.
Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
Technical Specifications
12.1-Inch Patient Monitor for Hospitals and Bedside Monitoring
This 12.1-inch patient monitor is a professional hospital patient monitor designed for continuous bedside monitoring of essential patient vital signs. It integrates ECG, SpO2, NIBP, TEMP, and RESP monitoring in one compact patient vital signs monitor, making it suitable for hospitals, clinics, wards, operating rooms, and other healthcare environments.
Key Features of the Patient Monitor
12.1'' TFT Color LCD Display
800 × 600 pixel high-resolution display provides clear visualization of patient vital signs and monitoring data.Standard 5-Parameter Patient Monitoring
Supports ECG, SpO2, NIBP, TEMP, and RESP, providing comprehensive patient vital signs monitoring for bedside care.Fanless Design
The fanless design provides quiet, energy-saving, and clean operation, making this hospital bedside monitor suitable for patient rooms and clinical environments.Multiple Monitoring Interfaces
Features a standard interface, OxyCRG, trend chart, big-character interface, and bed-view function for convenient hospital patient monitoring.Easy Operation
Supports both physical keys and buttons for simple and efficient operation by healthcare professionals.Up to 8-Channel Waveform Display
Displays up to 8 channels of patient monitoring waveforms on a single screen, allowing clinicians to review multiple vital sign parameters simultaneously.Flexible NIBP Measurement
Provides Manual, AUTO, and Continuous NIBP measurement modes. The monitor can store up to 1,000 groups of NIBP measurement data for patient monitoring and review.Alarm Event Review
Supports review of up to 71 alarm events for all monitored parameters and 60 arrhythmia alarm events, helping healthcare professionals track important patient changes.Drug Concentration and Titration Functions
Includes drug concentration calculation and titration table functions to support clinical treatment and medication management.One-Key Trend Data Printing
Trend table data can be printed with one key, providing convenient documentation of patient monitoring information.Central Monitoring System Connectivity
Supports connection to a Central Monitoring System through WiFi or wired mode, enabling centralized hospital patient monitoring and data management.AC/DC Power and Rechargeable Battery
Supports AC/DC power supply and includes a built-in rechargeable lithium battery for uninterrupted bedside patient monitoring during power transitions or patient transport.Defibrillation-Proof and Anti-Interference Design
Designed with protection against high-frequency surgical equipment interference and defibrillation. Special leads are required for defibrillation-proof operation.
Applications
This patient monitor is suitable for hospitals, clinics, wards, patient rooms, operating rooms, and other healthcare facilities requiring reliable bedside patient monitoring. As a compact hospital bedside monitor, it provides continuous monitoring of essential vital signs and can be connected to a central monitoring system for broader clinical monitoring.
Standard Parameters
ECG
| Lead mode | 3/5-lead (R, L, F, N, C) |
|---|---|
| Lead selection | I, II, III, avR, avL, avF, V |
| Waveform | 3 and 7 channel selectable |
| Gain selection | 0.5mm/mV, 1mm/mV, 2mm/mV |
| Sweep speed | 12.5mm/s, 25mm/s, 50mm/s |
| Heart rate range | Adult: 15~300bpm; Neonates/pediatric: 15~350bpm |
| Accuracy | ±1bpm or ±1%, whichever is greater |
| Resolution | 1bpm |
| Filter | Surgery mode: 1~20Hz; Monitor mode: 0.5~40Hz; Diagnostic mode: 0.05~130Hz |
| Scaling signal | 1mV, ±3% |
| Protection | Withstand 400VAC/50 voltage isolation against electroshock, interference and defibrillation |
| Alarm range | 15~350bpm |
| S-T segment detection - Measurement range | −2.0mV ~ +2.0mV |
| S-T segment detection - Alarm range | −2.0mV ~ +2.0mV |
| S-T segment detection - Accuracy | −0.8mV ~ +0.8mV |
| S-T segment detection - Error | ±0.02mV |
| Arrhythmia analysis | YES |
SPO2
| Measurement range | 0~100% |
|---|---|
| Resolution | 1% |
| Accuracy | ±2% (70~100%) / unspecified below 70% |
| Alarm range | 0~100% |
| Pulse Rate - Range | 20~300bpm |
| Pulse Rate - Resolution | 1bpm |
| Pulse Rate - Error | ±1bpm or ±2%, whichever is greater |
NIBP
| Method | Digital Automatic oscillometric |
|---|---|
| Operation mode | Manual / Automatic / Continuous |
| Auto measurement time | Adjustable (1~480min) |
| Measurement unit | mmHg / kPa selectable |
| Measurement types | Systolic, Diastolic, Mean |
| Systolic range - Adult | 40~270mmHg |
| Systolic range - Pediatric | 40~220mmHg |
| Systolic range - Neonates | 40~135mmHg |
| Mean range - Adult | 20~235mmHg |
| Mean range - Pediatric | 20~165mmHg |
| Mean range - Neonates | 20~110mmHg |
| Diastolic range - Adult | 10~215mmHg |
| Diastolic range - Pediatric | 10~150mmHg |
| Diastolic range - Neonates | 10~100mmHg |
| Over-pressure protection | Double safety protection |
| Resolution | 1 mmHg |
| Alarm | Systolic, Diastolic, Mean |
RESPIRATION
| Method | Thoracic impedance |
|---|---|
| Measurement range - Adult | 7~120rpm |
| Measurement range - Neonates/Pediatric | 7~150rpm |
| Apnea alarm | YES, 10~40s |
| Resolution | 1rpm |
| Accuracy | ±2rpm |
TEMP
| Compatible probe | YSI or CYF |
|---|---|
| Measurement range | 5~50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.1°C |
| Refreshing time | about 1s |
| Average measuring time | <10s |
Optional Parameters
RECORDER
| Type | Built-in, thermal array |
|---|---|
| Plethysmogram caveform | 2 channels |
| Record mode | Manual, on alarm, time defined |
| Recording width | 50mm |
| Printing speed | 50mm/s |
| Recording type | Frozen waveform record, NIBP recall record, Trend table record, Alarm record, Fixed-time record |
IBP (Invasive Blood Pressure)
| IBP Waveform | 2-Channel (Max 8 channels) |
|---|---|
| Measurement Range | −50 ~ +350mmHg |
| Resolution | 1mmHg |
| Unit | mmHg, kPa |
| Accuracy - Dynamic | ±4mmHg or 4%, whichever is greater |
| Accuracy - Sensitivity of transducer | 5 µV/V/mmHg, ±2% |
| Impedance of transducer | 300~3000 Ohm |
| Transducer sites | ART, PA, LAP, RAP, CVP, ICP, P1/P2 |
| Measurement range - ART | 0~+350mmHg |
| Measurement range - PA | −10~+120mmHg |
| Measurement range - CVP/RAP/LAP/ICP | −10~+40mmHg |
| Measurement range - P1/P2 | −50~+360mmHg |