Hospital UV Room Air Sterilizer for operating room FY 30FSI

  • Hospital UV sterilizer with 4×30W lamps (253.7nm) kills germs via DNA destruction, fits 60㎡, 15-1440min timer, motion sensor, lab-tested.

  • 428uW/cm² irradiance, 30-180° adjustable arms, 2/4 lamp control, auto-shutoff on motion, 220V.

  • For hospitals/schools etc., 15s delay, 30min+ sterilization, post-use ventilation, easy storage.

Description

Technical Specifications

    • Hospital medical UV Room sterilizer ,has four (4) 30 watts UV lamps that emit a high intensity ultraviolet light that hits every surface in the room and kills any micro organisms or pathogen including MRSA,hand foot mouth disease,colds and flu,pneumonia,molds,e.coli,salmonella and similar type bacteria.The light penetrates and destroys the actual DNA of micro organisms.There is no known micro organism that is  immune to UV-C energy.
    • UV Room Sterilizer disinfects approximately up to 60 square meters room area.
    • There are numerous safety features bulit with a 15-1440mins timer and  motion sensor.
    • UV Room Sterilizer has numerous applications not just for hospitals but can be used in schools,play areas,hotels,clinics,homes,cinemas,buildings,food manufacturing companies and offices;it quickly and effectively provide disinfection of all surfaces and air within minutes.
    • UV Room Sterilizer is laboratory tested ,used by hospitals and recommended by doctors.

Features:

    1. Tube Power:30W
    2. Number of tubes:Four(4)
    3. Application area:60 m2
    4. Voltage:220V±10%,Frequency: 50HZ±10%
    5. Input power:180VA
    6. UV Wavelength:253.7nm
    7. UV illumination: ≥428uW/cm2
    8. Can be operated with 2 or 4 lamps by pressing Lamp 1 or Lamp 2 button
    9. Lamps have side compartments for safe storage
    10. Angle of the lamp arms can be adjusted from 30-180°
    11. Timer can be set to desired duration starting from 15mins to 1440mins
    12. Auto-shut off feature is triggered when motion is detected.Sterilization automatically resumes once no further movement has been detected.

Usage Instruction:

1.clean the room  before using uv room sterilizer.

2.Carefully place the UV Room Sterilizer in the center of the room or on a spot where UV light can beam more things in the room.

3.Arrange everything found in the room to ensure they will be exposed to UV light.Place things that are touched more often closer to the system to maximize sterilization.

4.Plug in and set  the timer to the desired duration.The system has a time delay of 15 seconds upon timer setting,this allows the system operator to vacate the room.The UV light will be on after 15 seconds.Sterilization start .

5.UV Room Sterilizer will suspend and uv light will shut off if someone is around the machine.Then resume when people left.

6."Lamp 1 "control 2 lamps,'lamp 2"control another 2 lamps.

7.It will generate smell after sterilization.It's perfectly natural.Pls open the window to let the smell out after sterilization.

8.Wipe the lamps with dry cloth after sterilization.Carefully stow the arms in the arms door.